Cat 5e Riser

Cat 5e Riser                      

DOWNLOAD CAT 5e RISER PDF

 

Applications Top of Page


Gigabit Ethernet (1000BaseT), High Speed Voice/Data Applications, 100BaseT and 100BaseTX, Video to Desktop, ISDN and Multimedia, 55/155 Mbps ATM, 100Base VG ANYLAN. 

Conductors Top of Page

 24 AWG solid bare copper.

Assmbly Top of Page

 
4 twisted pairs cabled to a left-hand lay. Nylon ripcord for ease of jacket stripping.   

Insulation Top of Page

 Polyethylene; .036 in. O.D. 

Jacket Top of Page

 0.014" nominal wall gray flame-retardant polyvinyl chloride (PVC).

Industry Standards / Certifications Top of Page

UL Listed Type CMR
ETL Verified to TIA-568-B.2 Category 5e
C (UL) CMR
NEC Article 800
UL 1666 Riser Flame Test
RoHS Compliant 

Surface Print Top of Page

COMTRAN CORP. (01-12345) 24 AWG CMR C(UL)US ETL VERIFIED TO TIA 568-B.2 CAT 5e (MM/YY) RoHS 000002FT
 

    

       
Cerro Finished Goods Part #

Description

Put-UpPackage TypeSpools/Coils Per Master CartonShipping Weight Per Master CartonUPC Code
       
270-0104C 24G 4P Cat 5e Riser CMR Gray 100' Pre-Cut  100 Shrink Film 813.6000 048243994113 
270-0104J4 24G 4P Cat 5e Riser CMR Gray 500'  500Box18.5000048243994120 
270-0104K5  24G 4P Cat 5e Riser CMR Gray 1000' 1000Box 1 17.0000048243994137 

 270-0144K5

24-4 Pair Cat 5e Riser CMR Blue 1000'  1000Box 1 17.0000048243994144 
       

 

 Electrical Performance

         
Frequency MHzPSACR (min)ACR (min)Attenuation (max)PSNEXT (min)NEXT (min)PSELFEXT (min)ELFEXT (min)Return Loss (min)
         
1 60.363.32.062.365.360.863.8 20.0
4 49.252.24.153.356.348.8 51.8 23.0
10 40.843.86.547.350.3 40.8 43.8 25.0
1636.039.08.244.247.236.739.725.0
2033.536.59.342.845.834.837.825.0
2530.933.910.441.344.332.835.824.3
31.2528.231.211.739.942.930.933.923.6
62.518.421.417.035.438.424.927.921.5
10010.313.322.032.335.320.823.820.1
1551.44.428.129.432.417.020.0--
200----32.427.830.814.817.8--
250----36.926.329.312.815.8--
300----41.025.128.111.314.3--
350----44.924.1 27.1 9.9 12.9 --
         

Values are expressed in dB per 100 m (328 ft.) length.