Submersible Pump Cable - Flat
Twisted PVC Insulation
DOWNLOAD SUB PUMP CABLE - FLAT PDF

| Applications | Top of Page |
For use within a well casing to supply current to a submersible pump. For use where the cable is not subject to repetitive handling required by frequent pump-unit service. Maximum conductor operating temperature: 75°C at voltages not exceeding 600 volts. Minimum operating temperature is -25°C.
| Conductors | Top of Page |
7-Wire Stranded: soft, uncoated copper per ASTM-B8
| Assembly | Top of Page |
- All conductors, including the ground wire, are laid flat and parallel and are covered with a yellow PVC insulation rated 75°C (Type THW). This PVC compound forms an interconnecting web between the conductors.
- One conductor is marked with the sample surface print shown below plus sequential footage markings in black.
- One conductor is printed with red hash marks.
- The grounding conductor is marked with a continuous green stripe and "FOR GROUNDING ONLY."
- On three-conductor cables with ground, the fourth conductor is unmarked.
| Industry Standards | Top of Page |
UL 83
ASTM-B3
ASTM-B8
NFPA70: National Electrical Code®
| Surface Print | Top of Page |
Sample: 12 AWG (UL) THW SUBMERSIBLE PUMP CABLE 600 VOLTS 900 FT
Product Code Number | AWG Size | Number of Conductors |
| Insulation Thickness MILS. | Approx. Shipping Weight Lbs./M Ft. | Approx. Dimensions MILS | UPC Code |
|---|---|---|---|---|---|---|---|
| 141-2602J | 12 | 2 W/GRD | 7 x .0242 | 45 | 116 | 182 x 558 | 048243476824 |
| 141-2602k | 12 | 2 W/GRD | 7 x .0242 | 45 | 116 | 182 x 558 | 048243476848 |
| 141-2603J | 12 | 3 W/GRD | 7 x .0305 | 45 | 160 | 182 x 746 | 048243476862 |
| 141-2603K | 12 | 3 W/GRD | 7 x .0305 | 45 | 160 | 182 x 746 | 048243476886 |
| 141-2803J | 10 | 3 W/GRD | 7 x .0305 | 45 | 225 | 205 x 770 | 048243476947 |
| Package Code | J | K |
|---|---|---|
| AWG Size | 500' Spool or Reel | 1,000' Reel |
| 12 STRD. 2 W/GRD | X | X |
| 12 STRD. 3 W/GRD | X | X |
| 10 STRD. 3 W/GRD | X | |

Top of Page