Submersible Pump Cable - Twisted

Submersible Pump Cable Twisted
Twisted PVC Insulation

DOWNLOAD PUMP CABLE - TWISTED PDF


Application Top of Page

For use within a well casing to supply current to a submersible pump. For use where the cable is not subject to repetitive handling required by frequent pump-unit service. Maximum conductor operating temperature of 75°C not exceeding 600 volts.

Conductors Top of Page

Solid conductors: soft, uncoated copper per ASTM-B3

Grounding Insulation Top of Page

Color-coded PVC (polyvinyl chloride) rated 75°C (Type THW construction)
Three-conductor: Black, yellow and red with green ground
Two-conductor: Black and red with green ground

Grounding Conductors Top of Page

Solid conductor: soft, uncoated copper per ASTM-B3

Assembly Top of Page

The insulated conductors are twisted together.

Industry Standards Top of Page

UL 83
ASTM-B3
NFPA70: National Electrical Code®

Surface Print Top of Page

Sample: 12 AWG E39388 (UL) THW SUBMERSIBLE PUMP CABLE 600 VOLTS

 

       
Product Code
Number
AWG
Size
Number of
Conductors
Conductor
Standing
Insulation
Thickness MILS.
Approx. Net. Wt.
Lbs./M. Ft.
UPC
Code
       
141-1602E 12  2 W/GRD   Solid  45  95  048243477050
141-1602J 12  2 W/GRD  Solid 45 95 048243477043
141-1603E 12 3 W/GRD Solid 45 126 048243477098
141-1603J 12 3 W/GRD Solid 45 126 048243477081
       

  
Package CodeE
AWG Size150' Coil
  
12 STRD. 2 W/GRD  X 
12 STRD. 3 W/GRD X